Facts About
Energy Waste
A heating, cooling,
or refrigeration system is sized to achieve the desired space temperature
or refrigeration on the coldest and warmest days or level of utilization
that may be expected. As such, most heating, cooling, and refrigeration
systems are between 1.5 to 2 times larger than what is necessary
to maintain space temperature or refrigeration conditions on more
moderate days.
The relative
over-sizing for a heating system is greatest in the spring and fall
and for a cooling system in the early and late summer.
Due to this
over-sizing, the burner or compressor continuously cycles on and
off to prevent overheating or overcooling of the space. The on/off
cycling rate is directly related to the load on the system. The
system is not capable of determining that under conditions when
demand has greatly lessened that the cycling settings can be effectively
altered on a real-time basis to run significantly less to reflect
the actual need for cooling, heating, or refrigeration.
The IntelliCon®
Solution
In much the
same way as 'Outdoor Air Reset Control' improves system efficiency
by more closely matching the output of a boiler to the heating demand,
the IntelliCon patented technology has the same energy-saving effect
without the pitfalls and installation headaches.
The microprocessor
based controls continuously monitor the system's load via sensors
for heating systems, or by monitoring the compressor's on/off cycle
times for cooling/refrigeration systems.
Based on load
analysis, a computation is made of the optimum length of time that
the off-time cycle can be extended without materially affecting
the space or refrigerant conditions. The objective is, when demand
requirements have reduced, to keep the burner/compressor in the
off cycle for the longest possible period of time beyond when the
thermostat might have normally turned the system back on. Once this
period of extended off-time has elapsed, the burner/compressor begins
to operate again until the set point is reached, at which time,
it will shut off and the off-period begins again with the IntelliCon
determining the additional time that the burner/compressor can remain
off, while maintaining all HVAC and refrigeration requirements.
|